Home / About Us  / Contact Us / SEG Jobs  
  Synchronized Electricity      Solar Electricity      Wind Electricity   Generators | E-Quote        Service | Support

SYNCHRONIZED ELECTRICITY GENERATOR T/R

 2.0MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
FEATURES
LOWER COST
LOWER FIRST INVESTMENT BUDGET
COST EFFECTIVE & ECONOMICAL
SUSTAINABLE & RELIABLE SYSTEM

 2.8MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
PROTECTION SYSTEM
ENGINE PROTECTION
ALTERNATOR PROTECTION
CIRCUIT BREAKER PROTECTION

 3.3 MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
LOWER COST
LOWER FIRST INVESTMENT BUDGET
FLEXIBLE USAGE
CONSTANT PARALLEL WORKING

 4.0 MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
LOWER COST
LOWER FIRST INVESTMENT BUDGET
FLEXIBLE USAGE
CONSTANT PARALLEL WORKING

 5.0 MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
LOWER COST
LOWER FIRST INVESTMENT BUDGET
FLEXIBLE USAGE
CONSTANT PARALLEL WORKING

 5.6 MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
LOWER COST
LOWER FIRST INVESTMENT BUDGET
FLEXIBLE USAGE
CONSTANT PARALLEL WORKING

 6.0 MW ELECTRICITY PROJECT COST $ 0m
 TURN KEY SOLUTION
LOWER COST
LOWER FIRST INVESTMENT BUDGET
FLEXIBLE USAGE
CONSTANT PARALLEL WORKING

PROPOSED PACKAGE CAPACITY : 6.0 MW
Package Price for 6.0 MW Synchronized Electricity :$0M
Package Price for Grid Connected 6.0 MW Synchronized Electricity : Contact For Details Price
Note: This package offers without Transformer, VCB or SF6 RMU and container price.
  LIST OF MATERIALS
S/NDescription of materialsQuantity RequiredRemarks
1Cummins Diesel Engine Generators
Capacity: 1250KVA, 400 Volt & 50Hz
6x1250KVA=7500KVA
2
Generator Synchronization Control Panel
Model: ATSP09
6 no with common
Bus-bar
3
Air Circuit Breaker (ACB)
Capacity: 2000Amps, 3 pole
Brand: ABB/Schneider
6 no
4
Air Circuit Breaker (ACB)
Capacity:3500 Amps, 4 pole
Brand: ABB/ Schneider
4 no
5
Low Voltage Power Cable
Voltage: 400 V
Cable size: 630mm²
Single core, Copper conductor
Insulation: XLPE
2100 m
6
Grounding Cable
Size: 95mm², Y/G copper Conductor
100 m
7
Grounding Cable
Size: 35mm², Y/G copper Conductor
300 m
8
Grounding Cable
Size: 16mm², Y/G copper Conductor
100 m
9
Control Cable
800 m
10
External Fuel Tank
Capacity: 10K gallons
1 no
11
Fuel Pipes
500 m
12
Fuel Filter
12 no
13
Accessories
As per required
Options For The Above Package
14
Transformer Synchronization Panel
6 no
15
Step-up Power Transformer
(0.4KV/33KV or 0.4KV/11KV or as per client requirements)
Capacity: 1250 KVA, 50Hz
6 no
16
SF6 Breaker or VCB (Incoming Breaker)
Capacity: 400 Amps with all protection system
6 no
17
SF6 Breaker or VCB (Outgoing Breaker)
Capacity: 630 Amps with all protection system
3 no
18
High Voltage or Medium Voltage Power Cable
Cable size: 300mm², Three core, Copper conductor
Insulation: XLPE, Armored steel ware insulated
500 meter
19
20’ Container
6 no
Civil constrictions are the client responsibility
AGN should be to quote, If requested by client.
Read More details of the package......
 
 PROPOSED PACKAGE CAPACITY : 6.0 MW ( 7500 KVA )
Synchronized Electricity Generator T/R offers the full and complete 3.3 MW of electricity package as a turnkey solution. The enter package shall be install and test for client by Synchronized Electricity Generator T/R's engineering department.
Package Price for 6.0 MW Synchronized Electricity :$0M
Package Price for Grid Connected 6.0 MW Synchronized Electricity : Contact For Details Price
Note: Synchronized 5 generator (Diesel Engine) and through power to one common bas-bar.
Payment Terms:
60% advance along with at the time of contract singing, Balance 30% payment after delivery materials to site and remaining 10% will be payment at the time of project handover to the client.
Payment Terms for War Zone Countries:
80% advance along with at the time of contract singing, Balance 20% will be payment after delivery materials to the site.
Civil construction and site preparation:
Project related all civil construction and site preparation in the client responsibility.
Material Transportation:
Inside UAE:
Transport all material from Synchronized Electricity Generator T/R warehouse (in UAE) to site location is including with package price.
Outside UAE:
Transport all material from Synchronized Electricity Generator T/R warehouse (in UAE) to site location is the client responsibility.
Security and Synchronized Electricity Generator T/R's technical staff accommodations:
Inside UAE:
A security and Synchronized Electricity Generator T/R's technical staff accommodations in UAE is Synchronized Electricity Generator T/R's responsibility.
Outside UAE and warzone countries:
A security and Synchronized Electricity Generator T/R's technical staff accommodation in outside UAE & warzone countries is the client responsibility.
Price Change:
All Price are subject to change and alternation without prior notice. Should the prices changes during the contract, Synchronized Electricity Generator T/R will not change price for existing client contract.
Contract Cancelation Terms:
Once the contract is signed and fully discussed in details, the payment /deposit is for failed and non-refundable at any circumstance. Delay of payment shall be the same as the cancelation of the project the time both party agree up on.
SINGLE LINE DIAGRAM FOR 6.0 MW SYNCHRONIZED ELECTRICITY
MATERIAL DESCRIPTIONS AND DETAIL TECHNICAL SPECIFICATIONS
Engine Model: KTA50 Series Engine.
  Standby Rating Prime Rating
Model 50Hz kVA (KW) 60Hz kVA (KW) 50Hz kVA (KW) 60Hz kVA (KW)
C1400 D5 1400 (1120)N/A1250 (1000)N/A
Specification
Engine Specifications
Design4 cycle, in line, turbo Charged and after-cooled
Bore158.8 mm (6.25 in.)
Stroke158.8 mm (6.25 in.)
Displacement50 liter (3067in.3)
Cylinder Block EnginesSixteen-cylinder vee formation, direct injection, four-cycle diesel
Battery Capacity1800 amps at ambient temperature 32°F (0°C)
Battery Charging Alternator24-volt, negative ground
Starting Voltage 
Fuel SystemDirect injection
Fuel FilterDual spin on paper element fuel filters with standard water separator.
Air Cleaner TypeDry replaceable element
LOFTLOFT1
Standard Cooling System104°F (40 °C) ambient radiator,
Alternator Specification
DesignBrushless, 4 pole, drip proof revolving field
Stator2/3 pitch
RotorDirect coupled by flexible disc
Insulation SystemClass H
Standard Temperature RiseRise 125º C Standby
Exciter TypePMG (Permanent Magnet Generator)
Phase RotationA (U), B (V), C (W)
Alternator CoolingDirect drive centrifugal blower fan
AC Waveform Total Harmonic DistortionNo load < 1.5%. Non distorting balanced linear load < 5%
Telephone Influence Factor (TIF)<50 per NEMA MG1-22.43
Telephone Harmonic Factor (THF)No load < 1.5%. Non distorting balanced linear load < 5%

                  Standby Power
Standby power is defined as the maximum power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 500 hours of operation per year under average of 70% load. Overloading is not permissible.

                  Prime Power
Prime power is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hours.
SYNCHRONIZATION CONTROL PANEL SPECIFICATION
ATSP09 SYNCHRONIZATION CONTROL PANEL SPECIFICATIONS
LOAD PROPERTIES:
  • Automatic and manual synchronization
  • Can synchronized until 10 generators among them selves and feed the workload
  • Load sharing at generators according to power
  • Automatically start and stop according to load
  • Automatically balancing work hours (co-aging)
COMMUNICATION PROPERTIES:
  • Communication over (AQ) bus-bar with electronic engine control units (optional)
  • Alarm message with SMS (optional)
  • Open communication over RS 232 or RS 485 interface
  • Support Motbus RTU protocol (concordant with scada system)
INDICATOR PROPERTIES:
  • LCD text indicator
  • All engine and alternator parameters can be watched
  • Engine and alternator protection
  • Keep the records of generator alarms, last 25 records
  • Expansion modules (in and out)
With LCD screen in ATSP09 synchronization panels you can measure the following rates and with the stated protection, system reliability put in first place.
MEASUREMENTS:
DIRECT MEASURES:
  • Oil pressure
  • Coolant temperature
  • Fuel level (optional)
  • Oil temperature (optional)
  • Accumulator voltage
  • Engine circulation
  • Generator frequency
  • Generator phase-neutral voltage
  • Generator inter-phase voltage
  • Generator phase current
  • Generator earth current (optional)
  • Generator phase sequence
EXPANDABLE MEASUREMENTS:
  • Generator total active power (KW)
  • Generator total visible power (KVA)
  • Generator total reactive power (KVAr)
  • Generator average power factor (cosF)
HIDDEN MEASUREMENTS:
  • Actual time
  • Left time for the next (maintenance)
  • Generator positive KWh
  • Generator negative KWh
  • Generator KVAh
  • Generator KVArh
  • Number of starter
  • Maximum positive vector slide
  • Maximum negative vector slide
PROTECTION SYSTEM:
ENGINE PROTECTION:
  • Low oil pressure
  • High coolant water temperature
  • High oil temperature (optional)
  • Low/high frequency cycle
  • Battery charger rectifier error
  • Low/high accumulator voltage
  • Low/high fuel level (optional)
ALTERNATOR PROTECTION:
  • Low/high voltage
  • Low/high frequency
  • Extreme voltage
  • Earthling error (optional)
  • Reverse power
  • Wrong phase rotation of alternator
  • Excitation loss
CIRCUIT BREAKER PROTECTION:
  • Generator switching off error
  • Generator switching on error
MCCB TECHNICAL SPECIFICATION
Brand NameABB
Capacity1500Amps
P PoleThree
Frequency50Hz
DesignCompact
Serial number034798
NS100N
Vi750
Uimp8KV
Vc-389/240Icu 50,(V) 380/415~KA 50,440~50,500/525 ~ 40
660690 ~ 30,Ics 75% Icu,Icw 25 KA/.5s Cat-B
Protection systemGenerator switching off error,Generator switching on error,Over load
AIR CIRCUIT BREAKER SPECIFICATION
Brand nameABB
ModelE4S/f
Rated uninterrupted current(at 40 °C)Iu[A]3500
Number of poles4
Rated service voltage Ue [V ~]690
Rated ultimate short-circuit breaking capacity Icu 
220/230/380/400/415 V ~ [kA]80
440 V ~ [kA]80
500/660/690 V ~ [kA]75
Rated short-time withstand current Icw80
(1s) [kA]75
(3s) [kA] 
Rated short-circuit making capacity (peak value) Icm [kA] 
Application category(in accordance with IEC 60947-2)176
Isolation behavior (in accordance with IEC 60947-2)B
Overall DimensionsFixed- H = 418 mm - D = 302 mm L [mm] 746 ,Withdraw able- H = 461 - D = 396.5 mm L [mm] 774 ,Weights (circuit-breaker complete with releases and CT, not including accessories),Fixed [kg] 120 Withdraw able (including fixed part) [kg] 170 250

STEP-UP POWER TRANSFORMER SPECIFICATION
Capacity of power transformer1250kVA
DutyContinuous to suit Max. Ambient 50°C
TypeOil immersed Conservator type
CoolingONAN
Primary Voltage0.4KV
Secondary Voltage33kV or 20KV or 11 KV or as per client demand
Frequency50 Hz
No. of phase3
WindingCu wound
Vector GroupYNd11
Insulation class of windingClass A
Top oil50 °C
Winding55 °C
% Impedance7.5% +IEC TOL.
No load losses4.5 KW + IEC TOL.
HV terminationSide mounted cable box
LV terminationSide mounted cable box
Applicable StandardsIEC 60076
Over all dimension1350*1500*1500 mm
Total Weight7312 KG
AccessoriesTerminal marking plates,Tap Switch (Off- load),Rating Plate,Cooling fan/Radiators,2 No’s earthling terminals,Lifting lugs,Oil level gauge,Drain valve,Top filling hole & plug,Thermometer with max. pointer,Pressure relief device,OTI, WTI, Bucholz Relay

SF6 RMU TECHNICAL DETAILS
2 no’s of 630Amp triple pole, single break, 3- position (“ON”, “OFF” and “EARTH”) ring main switches, each with independent manually charged spring mechanism and fully rated earth switch with provision for earth and test of the cable.
2 no’s of air insulated cable boxes and cable clams suitable for a 3 – core cable up to 300mm².
1 no 250 Amps triple pole, vacuum circuit breaker, with independent manually charged spring mechanism and fully rated earth switch with provision for earth and test of the cable.
1 no air insulated cable box and clamp suitable for a 3- core cable up to 185mm².
1 no mimic diagram on front panel, complete with status indicator.
1 set of positive standard mechanical interlocks.
1 set of current transformer for relay protection.
1 no ABEVA make self powered relay type: MICOM P124 for O/C & E/F protection.
1 no 24V DC shunt trip coil for remote tripping of circuit breaker.
1 set of fully interlocked test access cover.
2 no’s of neon indicator lamps /phase comparator sockets for each ring switch.
1 no stud for earthling connection.
1 no pressure indicator and SF6 recharging facility.
1 no “PULL TO TRIP” mechanism (Suitable shrouded).
1 set of auxiliary terminal.
1 no operating handle.
1 no earth fault indicator, electrical Auto reset (240V AC), complete with solid core current transformer.
VACUUM CIRCUIT BREAKER (VCB) TECHNICAL SPECIFICATIONS
Rated voltageKV 20
Service voltageKV 20
Rated frequency HZ 50
Rated insulation levelKV rms 28
Impulse withstand voltage KV peakKV peak 75
3 second withstand currentKA rms 20
Peak withstand currentKA peak 63
Internal arc withstand currentKA rms 25
Bus-bar rated currentA 400
for spring loading 220V 50HZ
For protective relays, control, signaling 24V 50 HZ
For heating 220V 50HZ
Current transformer (CT) 3 No. ring type (Multiple CT) 150/5A(for metering) and 150/1A(for protection)
Potential Transformer (PT) 2 No. 20/0.4KV (Class0.5 & 50 VA)
Protection system Earth fault relay Over Current relay for 3 phase (RED YELLOW BLUE)Master trip relay (VAJ relay)Trip current supervision relay

LOW VOLTAGE CABLE TECHNICAL DETAILS
Cable Type Low voltage cable
Size of cable(Core*Area in mm²) 1*630
Applicable Standard IEC60502
Suitable of earthed/Unearthed system Earthed/unearthed system
Voltage grade (KV)KV 0.6/1 KV
Maximum rated conductor temperature°C 105 °C
Max. Allowed conductor temperature °C 250 °C
In Air 745
In Ground 1050
In Duct 1050
Material Annelid copper
Shape Standard circular conductor
Cross section area 630
Materials XLPE compound as per ISO7098
Normal thickness of insulationmm 2.00
Materials PVC
Extruded or Wrapped Extruded
Thickness of sheath (Min.)mm 2.10
Color of sheath Black
Overall diameter of cablemm 37.0
Approx. Net Weight of cableKg/Km 3869.0
Overall quantity tolerance% ±5%
Recommended minimum bending radiusmm 740
Max. DC resistance at 20·COhm/Km 0.047
Max. AC resistance at 70·COhm/Km 

FUEL TANK DESIGN SPECIFICATION
Capacity10,000 Gallons
ShapeCylindrical
Thickness8mm
PortInlet, Outlet (For Overflow)
Bottom stand1000mm Ht.
MaterialGrade A-36, Mild Steel
Painting SystemThe fuel tank shall be light in color to minimize heating of the fuel by radiant heat sources. Any plating or paint materials shall not be degraded by contact with the fuel
AccessoriesFuel drain (The fuel drain assembly shall be constructed at the bottom side of the fuel tank),Fuel Gauge,Man hole,Air Vent,Ladder,Walking Platform at the top

Technical information and values are according to ISO8528, ISO3046, NEMA MG1.22, IEC 600341, BS 49995000, VDE 0530 standards. All products manufactured according to ISO9001, ISO14001, OHSAS18001, TSE, CE standards. All information given in this specification set is intended for general purposes only. Due to a policy continuous improvement Synchronized Electricity Generator T/R reserves the right to amend details and specifications without notice and all information given is subject to the Synchronized Electricity Generator T/R's current condition of sales.
TBA: To Be Ask TBD: To Be Determined NA: Not Available N/A: Not Applicable
 
Engineering Consultancy
> Project Engineering Consultancy
>Tender Engineering Documents
> Power House Engineering
 >Power Plant Engineering
>Electricity Technical Support
>L V Electricity Consultancy
>M V Electricity Consultancy
>H V Electricity Consultancy
>Project Site Assessment
ReadMore